Zebra QLn320 Healthcare Printer: Specs and Buying Guide
The Zebra QLn320 Healthcare printer is a 3 inch direct thermal mobile label printer from Zebra's QLn family, sold as a separate Healthcare model with part numbers that start QH3. This guide covers the new QLn320 Healthcare unit in our listing, the standard QLn320 units we also carry, what the store data says about each, and how the model compares with the QLn220 Healthcare and the ZQ620. Jump to the QLn320 Healthcare specs table if you only need the numbers.
Zebra no longer sells the QLn320 Healthcare, but many sites still run QLn printers on carts and belts because their label templates, chargers and batteries are built around them. Whether you need one spare for a ward or a set of units to keep a fleet consistent, the sections below explain what to check before you order.
In this guide
- Products in our listing
- QLn320 HC specs from our listing
- What the Zebra QLn320 Healthcare printer is for
- Who the QLn320 Healthcare suits
- Key configuration choices
- Labels and media
- Setup and command languages
- Lifecycle and QLn320 Healthcare replacement options
- Buying checklist
- QLn320 range in our listing
- Common questions
Products in our listing
We list one new QLn320 Healthcare unit and two refurbished standard QLn320 units.
QH3-AUCA0M00-00 is new and the two QN3 units are refurbished, per their condition tags. Each comes with the 30-Day Tech Seller USA warranty; a manufacturer warranty is not guaranteed.
Need several QLn320 printers?
Tell us the quantity, model and interfaces you need and we will prepare a quote.
QLn320 HC specs from our listing
The table below comes from the spec data stored on our QH3-AUCA0M00-00 listing. Values the listing does not record are shown as Not listed.
| Spec | QH3-AUCA0M00-00 (QLn320 Healthcare) |
|---|---|
| Condition | New |
| Product type | Mobile label printer |
| Print method | Direct thermal |
| Resolution | 203 dpi |
| Max print width | 2.9 in (72 mm) |
| Media width | 1.0 to 3.125 in (25 to 79 mm) |
| Print speed | Up to 4 ips (102 mm/sec) |
| Connectivity | USB, Serial, Bluetooth, Wi-Fi |
| Memory | 128 MB RAM, 256 MB Flash |
| Display | LCD, 240 x 128 pixels |
| Battery | 2450 mAh removable Li-Ion; optional 4300 mAh extended |
| Sealing rating | IP43 (IP54 with soft case) |
| Operating temperature | -4 to 122 F (-20 to 50 C) |
| Dimensions | 4.6 x 3.3 x 6.8 in (117 x 84 x 173 mm) |
| Weight | 1.6 lbs |
| Programming | Not listed |
| Warranty | 30-Day Tech Seller USA |
These figures line up with the QLn320 values in Zebra's QLn series datasheet, which lists a 72 mm (2.9 in) print width, 203 dpi resolution, up to 4 in per second, 128 MB RAM and 256 MB flash, and IP43 dust and water resistance or IP54 with the soft case. Zebra's datasheet lists CPCL, EPL and ZPL II as programming languages; our Healthcare listing does not record programming, so confirm the language your application uses.
What the Zebra QLn320 Healthcare printer is for
The QLn320 Healthcare is a belt or cart printer for labels printed where the work happens. Zebra's QLn datasheet names bedside specimen labels and pharmacy labels as healthcare applications for the QLn family. A 3 inch printer gives room for a readable patient name, a barcode and supporting text on one label, and the large 240 x 128 pixel display helps staff see printer status without a separate screen.
Our healthcare label and wristband hardware guide explains where mobile printers fit next to desktop and wristband printers, and the Zebra healthcare label printers guide covers how to specify Zebra's healthcare range more widely.
This guide does not make claims about the QLn320 Healthcare's housing materials, cleaning agents or regulatory approvals. If your organization has written requirements for equipment used near patients, review Zebra's own documentation with your clinical engineering, infection prevention and IT teams. We cannot promise that any printer meets a specific hospital's requirements.
Who the QLn320 Healthcare suits
The best fit for the Zebra QLn320 Healthcare printer is a site that already runs QLn320 Healthcare units and wants matching ones. Keeping the same model means existing batteries, chargers, cradles and label templates carry over and staff do not need retraining. It also suits teams that prefer one model across every ward so spares can move between departments.
A smaller clinic might buy one unit as a hot spare. A larger group might replace failed units one for one while it plans a move to a current Zebra model. Both are sensible, and we quote single units and larger orders in the same way. Buyers starting a new deployment with no existing QLn fleet should weigh the ended Zebra support against the price and familiarity of the QLn platform.
Key configuration choices
Healthcare or standard model. Our listing includes both the QLn320 Healthcare (QH3 part number) and the standard QLn320 (QN3 part numbers). They share the 3 inch Zebra QLn320 mobile label printer format, but they are separate Zebra models. If your organization specifies the Healthcare version, order the QH3 unit; if it does not, the standard QLn320 units are a refurbished alternative. Our store data records 3 inches of print width on the QN3 units and 2.9 in on the QH3 unit, so check the exact figure against your label layout.
Interfaces. Our QH3-AUCA0M00-00 listing records USB, Serial, Bluetooth and Wi-Fi. Zebra's datasheet lists USB 2.0, RS-232C serial, an 802.11n WLAN option and Bluetooth 3.0 for the QLn320, plus 10/100 Ethernet through a docking cradle. The QN3 units record Wi-Fi and Bluetooth. Our printer connectivity guide explains the tradeoffs, and the Wi-Fi for mobile devices guide covers roaming and coverage planning that applies in any large building.
Battery. For the QLn320 HC battery, the Healthcare listing records a 2450 mAh removable Li-Ion battery with an optional 4300 mAh extended battery. For long shifts the extended battery or a set of spares makes sense. Confirm battery and charger part numbers against the printer before you order, and read our battery safety, storage and shipping guide before stocking spares.
Resolution and speed. The Healthcare unit prints at 203 dpi and up to 4 in per second. That suits typical patient and specimen labels with 1D or 2D barcodes.
Labels and media
The Zebra QLn320 Healthcare printer is direct thermal, so there is no ribbon. Our listing records media widths from 1.0 to 3.125 in, which covers common 2 in and 3 in labels as well as narrower specimen labels. Direct thermal stock is sensitive to heat and light, so store rolls in a cool, dark place and rotate stock so older rolls are used first.
When changing label stock, print a test label and scan it with the same scanners staff use at the bedside or in the lab. Our direct thermal vs thermal transfer guide explains how direct thermal labels behave over time, and the label media selection guide covers adhesives and face stocks for different surfaces.
Setup and command languages
Zebra's QLn datasheet lists CPCL, EPL and ZPL II for the QLn320. Our standard QLn320 listings record ZPL and ZPL II. Most applications that already print to Zebra mobile printers send ZPL or CPCL, so a like for like QLn320 replacement usually needs only pairing or network setup. The ZPL vs ESC/POS guide explains why ZPL dominates label printing.
A practical setup sequence:
- Charge the battery fully before first use.
- Load a roll of the label stock you use today and calibrate the media.
- Pair over Bluetooth or join the Wi-Fi network, then print a configuration report to confirm settings and firmware.
- Send a test label from your application and scan it.
For a wider view of Zebra's mobile range, see our Zebra mobile label printers guide and the general mobile label printers buying guide.
Lifecycle and QLn320 Healthcare replacement options
Zebra's QLn320-HC support page states that Zebra is no longer offering the product for sale and that its resources will no longer be updated. The page names the ZQ620 Plus-HC as the replacement. It lists a last sale date of May 31, 2019 and a service and support end date of August 30, 2024, which it gives for QLn220 and QLn320 models in general rather than naming the HC version.
In our listing the closest comparisons are the Zebra QLn220 Healthcare (QH2-AUNA0M00-00), a 2 inch Healthcare model in the same family, and the Zebra ZQ620 (ZQ62-HUWA000-00). Our store data does not identify that ZQ620 unit as a Plus-HC model, so treat it as a standard ZQ620 when comparing.
| Feature | QLn320 Healthcare (QH3-AUCA0M00-00) | QLn220 Healthcare (QH2-AUNA0M00-00) | ZQ620 (ZQ62-HUWA000-00) |
|---|---|---|---|
| Condition | New | Refurbished | Refurbished |
| Max print width | 2.9 in (72 mm) | 2 inches | 2.8 inches (72 mm) |
| Print speed | Up to 4 ips | Not listed | Up to 4.5 in/sec |
| Connectivity | USB, Serial, Bluetooth, Wi-Fi | Wi-Fi, Bluetooth | 802.11ac Wi-Fi, Bluetooth 4.2 |
| Memory | 128 MB RAM, 256 MB Flash | Not listed | 512MB Flash / 256MB RAM |
| Programming | Not listed | ZPL, ZPL II | CPCL, EPL, ZPL |
| Weight | 1.6 lbs | 1.4 lbs | 1.6 lbs |
Our Zebra ZQ610 vs ZQ620 guide covers the ZQ600 family in more depth, and the Zebra ZQ630 guide covers the 4 inch model if you need wider labels.
Buying checklist
For the new QH3 unit and the refurbished QN3 units alike, check the following on arrival. Our refurbished grading guide explains how we describe condition on refurbished items.
- Print quality. Print a configuration report and a full label, and look for white lines that point to printhead wear.
- Battery health. Charge fully and run a normal shift of printing to confirm runtime.
- Interfaces. Confirm the radios and ports match the listing and your network plan.
- Media path. Open and close the media cover and check that the roll seats and feeds straight.
- Cleaning. Follow Zebra's cleaning instructions and our thermal printer maintenance guide to keep the printhead clear.
Returns, if needed, follow our 30 day policy with a 25% restocking fee that is waived for defective or wrongly shipped items. Orders ship with FedEx or DHL.
QLn320 range in our listing
| Part number | Model | Condition | Store specs |
|---|---|---|---|
| QH3-AUCA0M00-00 | QLn320 Healthcare | New | 2.9 in print width, 203 dpi, USB, Serial, Bluetooth, Wi-Fi |
| QN3-AUNA0M00-00 | QLn320 | Refurbished | 3 inches print width, Wi-Fi, Bluetooth, ZPL |
| QN3-AUNA0E00-00 | QLn320 | Refurbished | 3 inches print width, Wi-Fi, Bluetooth, ZPL |
Browse more models on the Zebra printers collection or the full printers collection.
Keeping a QLn fleet running?
Ask for a quote on QLn320 Healthcare units, standard QLn320 units or a mix.
Common questions
Is the Zebra QLn320 Healthcare still sold and supported by Zebra?
Zebra states on its QLn320-HC support page that it is no longer offering the product for sale. The same page lists August 30, 2024 as the end of service and support for QLn220 and QLn320 models, so plan on independent service and spares.
What replaced the Zebra QLn320 Healthcare?
Zebra names the ZQ620 Plus-HC as the replacement on the QLn320-HC support page. Our listing includes a standard Zebra ZQ620 configuration, which is not identified as a Plus-HC model in our store data.
What is the print width of the QLn320 Healthcare?
Our QH3-AUCA0M00-00 listing records a maximum print width of 2.9 in (72 mm) on media from 1.0 to 3.125 in wide, at 203 dpi and up to 4 inches per second.
What battery does the QLn320 Healthcare use?
Our listing records a 2450 mAh removable Li-Ion battery with an optional 4300 mAh extended battery. Confirm the battery part number against the printer before ordering spares.
Zebra QLn320 Healthcare vs QLn320: how are they different?
Both are 3 inch Zebra QLn320 mobile printers. The Healthcare version is a separate Zebra model with its own part numbers starting QH3. This guide makes no claims about its housing materials or cleaning compatibility, so check Zebra documentation for those details.
Does the QLn320 Healthcare need a ribbon?
No. Our listing records direct thermal printing, so it prints onto heat sensitive label stock without a ribbon.
Ready to order QLn320 printers?
Request a quote for a single spare or a full ward rollout.



